mgh189 8 360/0.476 1568160 7:12:49 01/07/1991 mgh189.dat 212 338(-453)/mV 12 0 -374 -18685 0 ECG lead I mgh189.dat 212 250(-35)/mV 12 0 -17 15699 0 ECG lead II mgh189.dat 212 196(-31)/mV 12 0 -22 -24059 0 ECG lead V mgh189.dat 212 11.86(-1463)/mmHg 12 0 -14 1728 0 ART mgh189.dat 212 1000 12 0 -1045 -26199 0 PAP mgh189.dat 212 1000 12 0 -1042 27522 0 CVP mgh189.dat 212 1000 12 0 -18 14419 0 Resp. Imp. mgh189.dat 212 1000 12 0 993 4195 0 CO2 #: 29 : M : Multiple trauma; Exploratory laparotomy; Splenectomy; Craniotomy # GENERAL COMMENTS: # Power off to data collection system @ 20 min # Stop/FFW tape @ 20 min - 21 min # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Sinus tachycardia @ 140 bpm # TECHNICAL COMMENTS: # Shivering, movement artifact # HEMODYNAMIC DATA: # ART: 130/80 (pedal) # RAP: 6 ICP:3 # WAVEFORM PATTERNS: # Pulsus paradox # Elevation of arterial pressure during shivering # TECHNICAL COMMENTS: # ICP on AUX CH10 # CVP tracing not recorded # Arterial pop-test 18.2 Hz # RESPIRATORY DATA: # RATE: 12/25 bpm # MODE OF VENTILATION: # Intermittent mandatory ventilation