mgh080 8 360/0.476 1151280 15:27:28 07/06/1991 mgh080.dat 212 375(-318)/mV 12 0 -327 -29336 0 ECG lead I mgh080.dat 212 295(-64)/mV 12 0 -5 -2697 0 ECG lead II mgh080.dat 212 288(-92)/mV 12 0 -25 -30433 0 ECG lead V mgh080.dat 212 11.99(-1444)/mmHg 12 0 -6 -1935 0 ART mgh080.dat 212 20 12 0 1519 -21011 0 PAP mgh080.dat 212 19.02(-956)/mmHg 12 0 -985 22365 0 CVP mgh080.dat 212 1000 12 0 -17 -5263 0 Resp. Imp. mgh080.dat 212 1000 12 0 987 -8568 0 CO2 #: 70 : M : Resection and grafting of abdominal aortic aneurysm; Colectomy /colostomy # PERTINENT HISTORY: # Low systemic vascular resistance due to dysfunction from spinal cord lesion # PHARMACOLOGIC SUPPORT: # Neosynephrine @ 16 mcg/min # GENERAL COMMENTS: # Kinetic bed in use # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Normal sinus rhythm with right bundle branch block @ 76 bpm # ECG INTERPRETATION: # Left axis deviation # Possible lateral infarct, age undetermined # Non-specific sn wave changes # Left atrial hypertrophy # HEMODYNAMIC DATA: # ART: 120/70 # RAP: 20 # RESPIRATORY DATA: # RATE: 10/10 bpm # MODE OF VENTILATION: # Intermittent mandatory ventilation # CO2 RECORDING