s20601 2 250 21300000 14:44:00 11/07/1988 s20601.dat 212 200/mV 12 0 -21 -431 0 V4 s20601.dat 212 200/mV 12 0 12 -12302 0 MLIII #Age: 46 Sex: F #Comments: # There is an ischemic episode in lead 1 at 22:22:30 # which is corrupted with noise. This patient demonstrated # a few ischemic episodes, manifested by ST depression # in both leads. The changes were minimal, and in some # cases the associated heart rate increases introduced # severe noise. #Symptoms during Holter recording: No data #Diagnoses: Syndrome X #Treatment: # Medications: None # Balloon Angioplasty: No data # Coronary Artery bypass Grafting: No data #History: # Effort and resting angina # Hypertension: No # Left ventricular hypertrophy: No # Cardiomyopathy: No # Valve disease: No # Electrolyte abnormalities: No # Hypercapnia, anemia, hypotension, hyperventilation: No # Atrioventricular nodal conduction delay: No # Intraventricular conduction block: No # Previous Myocardial Infarction: No # Previous tests: # ECG stress test: Yes # Date: No Data # Findings: Positive for ST depression of 0.1 mV in V3-V6 # Thallium/Stress echo: No data # Left ventricular function: # Normal # Echocardiogram: No data # Coronary Arteriography: # Normal coronary tree # Baseline ECG: # Normal #Holter Recording: # Date: 11/07/1988 # Recorder: ICR