mgh072 8 360/0.476 1857600 8:41:18 12/08/1991
mgh072.dat 212 284(-418)/mV 12 0 -364 6292 0 ECG Lead I
mgh072.dat 212 304(-146)/mV 12 0 -12 10346 0 ECG Lead II
mgh072.dat 212 217(-48)/mV 12 0 -27 -17477 0 ECG Lead V
mgh072.dat 212 11.85(-1128)/mmHg 12 0 -12 23196 0 ART
mgh072.dat 212 12.18(-853)/mmHg 12 0 -627 18017 0 PAP
mgh072.dat 212 20 12 0 -1036 7000 0 CVP
mgh072.dat 212 1000 12 0 -21 -3148 0 Resp. Imp.
mgh072.dat 212 1000 12 0 976 -25701 0 CO2
#<age>: 78 <sex>: F <diagnoses>: Coronary artery bypass graft
# PHARMACOLOGIC SUPPORT:
# Dopamine @ 200 mcg/min
# TNG @ 64 mcg/min
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
# Atrial pacing @ 75 bpm for cardiac output support
# RHYTHM DISTURBANCES:
# Left bundle branch block
# Atrial ectopy
# Multifocal ventricular ectopy
# First degree heart block
# Loss of atrial capture @ 36 min
# Pacing discontinued @ 37 min
# PACEMAKER INFO:
# Temporary atrial fixed rate pacing (AOO)
# Epicardial wires
# Medtronic 5330 pulse generator (MA 20)
# ECG INTERPRETATION:
# Inferior infarct
# Left atrial enlargement
# HEMODYNAMIC DATA:
# ART: 176/28 MEAN: 85
# INTRA-AORTIC BALLOON DATA:
# 40 cc balloon
# Aries console
# 1: 1 balloon ratio
# PAP: 27/10 PCW: 11 (@ 20 min, 65 min)
# RAP: 11 CI: 1.6
# WAVEFORM PATTERNS:
# Radial and aortic lumen IABP traces
# Timing adjusted @ 64 min
# TECHNICAL COMMENTS:
# PAP/CVP/LAP on same transducer
# Left atrial tracing @ 69 min - 70 min
# CVP tracing @ 71 min
# RESPIRATORY DATA:
# RATE: 7/7 bpm
# MODE OF VENTILATION:
# Controlled