MGH/MF Waveform Database 1.0.0

File: <base>/mgh006.hea (1,561 bytes)
mgh006 8 360/0.476 1626197
mgh006.dat 212 1185(-48)/mV 12 0 -645 42598 0 ECG lead I
mgh006.dat 212 1185(50)/mV 12 0 -854 2014 0 ECG lead II
mgh006.dat 212 1185(102)/mV 12 0 -868 56214 0 ECG lead V
mgh006.dat 212 11.91(-1227)/mmHg 12 0 -1528 59788 0 ART
mgh006.dat 212 20.26(-991)/mmHg 12 0 -1349 64864 0 PAP
mgh006.dat 212 20.06(-1007)/mmHg 12 0 -1431 12606 0 CVP
mgh006.dat 212 1000 12 0 -985 37349 0 Resp. Imp.
mgh006.dat 212 1000 12 0 182 60721 0 CO2
#<age>: 72 <sex>: M <diagnoses>: Endocarditis; Sepsis
# PHARMACOLOGIC SUPPORT:
#   Dopamine @ 950 mcg/min
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
#   Ventricular pacing @ 100 bpm for sinus rhythm with A-V dissociation
# PACEMAKER INFORMATION:
#   Temporary ventricular fixed rate pacing (VOO)
#   Transvenous wires (USCI bipolar #4)
#   Medtronic generator (output 5 mv)
#   Non-functional permanent coplin lithium pacer
# TECHNICAL COMMENTS:
#   Pacer mode (CH2) activated @ 22 min
#   Persistent ECG interference
# HEMODYNAMIC DATA:
#   ART: 120/50   	MEAN: 72
#   PAP: 47/20   	PCW: 17(@ 20 min, 32 min, 39 min)
#   RAP: 11
# WAVEFORM PATTERNS:
#   Intermittent cannon waves in CVP and PCW due to A-V asynchrony
# TECHNICAL COMMENTS:
#   CVP transduced with medications infusing simultaneously via pump
#   CVP on without medications @ 9 min - 11 min
#   Simultaneous CVP and PCW recording @ 20 min
# RESPIRATORY DATA:
# RATE:   8/22 bpm
# MODE OF VENTILATION:
#   Intermittent mandatory ventilation
# CO2 RECORDING:
#   Datex sidestream sensor
#   CO2 monitor malfunction @ 36 min, turned off