Icelandic 16-electrode Electrohysterogram Database 1.0.0

File: <base>/ice029_p_2of2.hea (1,813 bytes)
ice029_p_2of2 16 200 728000
ice029_p_2of2.dat 16 131.068/mV 15 0 0 -18025 0 EHG1
ice029_p_2of2.dat 16 131.068/mV 15 0 0 29832 0 EHG10
ice029_p_2of2.dat 16 131.068/mV 15 0 0 31096 0 EHG11
ice029_p_2of2.dat 16 131.068/mV 15 0 0 11444 0 EHG12
ice029_p_2of2.dat 16 131.068/mV 15 0 0 4948 0 EHG13
ice029_p_2of2.dat 16 131.068/mV 15 0 0 -13017 0 EHG14
ice029_p_2of2.dat 16 131.068/mV 15 0 0 22462 0 EHG15
ice029_p_2of2.dat 16 131.068/mV 15 0 0 -2414 0 EHG16
ice029_p_2of2.dat 16 131.068/mV 15 0 0 -4288 0 EHG2
ice029_p_2of2.dat 16 131.068/mV 15 0 0 27582 0 EHG3
ice029_p_2of2.dat 16 131.068/mV 15 0 0 -20179 0 EHG4
ice029_p_2of2.dat 16 131.068/mV 15 0 0 -28099 0 EHG5
ice029_p_2of2.dat 16 131.068/mV 15 0 0 7553 0 EHG6
ice029_p_2of2.dat 16 131.068/mV 15 0 0 8751 0 EHG7
ice029_p_2of2.dat 16 131.068/mV 15 0 0 18921 0 EHG8
ice029_p_2of2.dat 16 131.068/mV 15 0 0 16642 0 EHG9

#Info:
#ID:ice029
#Record type:pregnancy
#Record number:2/2
#Age(years):25
#BMI before pregnancy:24.5
#BMI at recording:28.8
#Gravidity:3
#Parity:2
#Previous caesarean:No
#Placental position:Anterior/Superior
#Gestational age at recording(w/d):34/5
#Gestational age at delivery:35/3
#Mode of delivery:Vaginal/Induction
#Synthetic oxytocin use in labour:Yes
#Epidural during labour:Yes
#Comments for recording:
#Midwife connects heart rate monitor at 00:21:12. Creates small overlap on 
#band of tocodynamometer. Possibly creates a small interference on electrode 1.
#The gap in the TOCO trace is artificial (the midwife pressed the paper feed button
#by accident). The gap occurs at around 25 minutes. Time labels on TOCO trace
#are possibly not in the correct places.
#Comments for delivery:
#Synthetic oxytocin started 3 hours before the baby was born.
#Epidural started 2 hours before baby was born.