The CirCor DigiScope Phonocardiogram Dataset 1.0.1

File: <base>/training_data/84732.txt (622 bytes)
84732 2 4000
AV 84732_AV.hea 84732_AV.wav 84732_AV.tsv
MV 84732_MV.hea 84732_MV.wav 84732_MV.tsv
#Age: Neonate
#Sex: Female
#Height: 49.0
#Weight: 3.365
#Pregnancy status: False
#Murmur: Present
#Murmur locations: MV
#Most audible location: MV
#Systolic murmur timing: Early-systolic
#Systolic murmur shape: Decrescendo
#Systolic murmur grading: I/VI
#Systolic murmur pitch: Low
#Systolic murmur quality: Blowing
#Diastolic murmur timing: nan
#Diastolic murmur shape: nan
#Diastolic murmur grading: nan
#Diastolic murmur pitch: nan
#Diastolic murmur quality: nan
#Campaign: CC2015
#Additional ID: nan