VisitPhysionetDirectoryProtocolFilenameFormatChannelsSampling rateLabeldescriptionunitsCalibrationEquipmentDevice output sampling rateExperiment
ScreeningNot uploadedScreeningICF
TCD window
Blood draw
PCP permission
ScreeningData/ECG24 hour ECG and EMG monitoringme6000ME6000 files (ECG and EMG files were recorded during the protocol walking test, and during the daily activity and sleeping)
12 min walkME600051000Hz
sit-to-stand testS####ECG.dat
sleepS####ECG.hea1ECG 1CH1 V5/V6-L clavicle
2ECG 2CH2 V1/V2 L clavicle
3foot switchright
4foot switchleft
5EMGgastrocnemius right
6EMGgastrocnemius left
7accelerometer
8empty
Visit 1Not uploadedRetinal ImagingRetinal Imaging
Visit 1Not uploadedCognitive testingCognitive
Visit 1Data/PedarPedar12 minute walkWalk test 1&2 ( walk1 around 11 am and walk 2 in the afternoon, normal hallway walking for 12 min recorded with EMG channels using ME6000)
and foot pressure distribution using pedar moile, some subjects also have Portapress beat-to-beat blood pressure
Walking test- foot pressure distribution and walking characteristics using Pedar Mobile
S####DA.ASC_PedarDAT
S####DA.ASC_PedarHEA
16
header: filename, left insole #, right insole #, mean step left, mean step right, min and max step, total time (s econds), distance ( meters),velocity (m/s)
1step_no
2foot
3max. force[N]
4mean force[N]
5max pressure [N/cm²]
6start
7start in % of total time
8stride
9step
10stance
11stance in % of stride
12swing
13swing in %
14init double in %
15single limb support %
16terminate double %
Visit 2Data/labviewLabviewHead up tiltVasoreactivity, Valsalva maneuver, Head up tilt
with TCDTCD
Valsalva manuever
5 min supine baselineS#####DB.datLabview10500
3 min hyperventilation
3 min CO2 rebreathing1Marker
5 min supine rest2ECG
Head up tilt 10 min3ABP
4Mcar
5Mcal
6Radi
7Therm
8Flow
9O2
10Co2
Day 2data/labviewlabview-sit-to-standSit-to stand with eyes open and closed
5 min sitting with eyes open on balance platform with simultaneous cardiovascular, TCD
5 min standing with eyes open on balance platform with simultaneous cardiovascular, TCD and balance measures
5 min sitting with eyes closed on balance platform with simultaneous cardiovascular, TCD
5 min standing with eyes closed on balance platform with simultaneous cardiovascular, TCD and balance measures
S#####DC.dat Labview151000
1Marker
2ECG
3ABP
4Mcar
5Mcal
6Radi
7Therm
8Flow
9O2
10Co2
11fx
12fy
13fz
14px
15py
Day 2Not uploaded3TMRIAnatomial and perfusion MRIMRI- anatomical, CBF regional perfusiona dn paerfusion in vascular territories; CO2 vasoreactivity to hyperventilation and C02 rebreathing
3Tesla GE Signa Vhi or Excite scanner and phase arrays head coil ( GE Medical Systmes, Milwaukee, WI)
MP-RAGE
MP-RAGE) (repetitionml or % of total brain volume
time [TR]/echo time [TE]/inversion time [TI]  7.8/3.1/600
msec, 3.0 mm slice thickness, 52 slices, bandwidth  122 Hz
per pixel, flip angle  10°, 24 cm  24 cm field of view [FOV],
256  192 matrix size)
FLAIRfluid-attenuated inversion recovery
(FLAIR) (TR/TE/TI  11,000/161/2,250 msec, 5 mm slice
thickness, 30 slices, bandwidth  122 Hz per pixel, flip angle 
90°, 24 cm  24 cm FOV, 256  160 matrix size),
DWIdiffusion-weighted image (b value of 1,000 seconds/
mm2, TR/TE  10,000/86.6 msec, 5 mm slice thickness, bandwidth
 250 kHz, 128  128 matrix size
CASLCBFthree-dimensional stack ofmL · 100 g1 · min1
interleaved spirals fast spin echo sequence (TR/TE  6,000/
23.8 msec, echo train length  66, with a 18  18 cm FOV, in
the coronal plane and 64 slices with thickness  3.8 mm, eight
Transcranial Doppler